Task

The filters in industrial vacuums become clogged after a time. The vacuum is run in alternating suction and pressure mode to clean the filter. It should be possible to change the intervals without changing the process control program.

Solution description

The different intervals for suction and pressure operation are effected with a clock generator, and can be adjusted by the end user.

Benefit/added value

– Small size allows installation in tight spaces
– End user can set the intervals as needed