MenuProduct searchSearch
Home » Applications » Flow­ measurement

Flow­ measurement

Simple throughput measurement for a centrifugal pump.
Industry:
Pumps and compressors
Series/Measures
Power reading converter
Product:
G2BA480V12A 4-20mA
Data sheet:
Task:
Simple throughput measurement for a centrifugal pump.
Solution
A power reading converter can be used as a simple, low-cost method for measuring the throughput of a centrifugal pump. The power consumption of a centrifugal pump is proportional to the volume being pumped. The measured power can be translated directly into the throughput.
Use/value:
- Dry running protection can be implemented at the same time
- Nothing needs to be installed in the system