Chipper

Chipper blockage should be recognised quickly. Monitoring of 2 overload thresholds: threshold 1 = reverse, threshold 2 = shutdown
Industry:
Processing machines
Series/Measures
Power measurement
Product:
G4BM480V12ADTL20
Data sheet:
Task:
Chipper blockage should be recognised quickly. Monitoring of 2 overload thresholds:
threshold 1 = reverse, threshold 2 = shutdown

Solution
Power monitoring for the electric motor of a chipper with the double “over” function. As soon as the effective power leaves the permitted range and exceeds the first overload threshold, relay output 1 is tripped and the machine is reversed. When the second overload threshold is exceeded, relay output 2 is tripped, the motor contact is switched off, and the system is shut down.

Use/value:
- Rapid shutdown in the event of blockage
- Monitoring of 2 separate overload thresholds
- Motor protection
- Minimisation and prevention of downtime